Discovered Values

My stove is a Piazzetta 220 M

RAM (0x00)

ADDR (HEX) ADDR (DEC) Formula Unit Description Example or default value Range
0x01 1 x/2 °C Ambient temperature. Follows the remote control sensor while the remote is in contact, falls back to the stove sensor when it is not (manual §18: fallback after 4 min without contact) 40 (== 20)
0x04 4 x Bool Hot enough for the room fan (0 = no, 2 = yes)
0x0A 10 x Room fan drive value: 0 off, 21 / 23 / 25 at speed 1 / 2 / 3 (verified 16/11/2026, stove working) 23
0x0B 11 Unknown, 0 if off ~ 100 if on
0x0D 13 x/10 rpm Auger speed
0x11 17 x Countdown counter 20 -> 0 / sec
0x13 19 Countdown Counter ? 120 -> 0
0x14 20 Unknown Boolean value
0x15 21 x id Last selected menu parameter (same ids as 0x18); set by the stove when a menu is opened 0
0x16 22 x count Key repeat counter: 1 on a key press, +1 for every auto-repeat step while the key is held (reached 37 after ~9 s); each step also steps the edit value 0x19. Back to 0 about 1 s after release (verified 17/11/2026 with /api/keywatch) 0
0x18 24 x id Parameter being edited on the RC (0 = not editing) - See lookup table. Writable, but clearing it does not confirm 0
0x19 25 x Menu edit value: the value the RC shows for the parameter in 0x18 (e.g. INSTELL WIRELESS 0 = off, 1 = on). Writable, but has no effect until confirmed on the RC
0x1A 26 x id Menu on the RC - See lookup table. Writable: the RC follows 0
0x21 33 x state Stove State 0
0x22 34 Unknown Boolean value
0x23 35 Countdown Counter 8 -> 0
0x24 36 Set to 3 – 7 on a key press and counts down to 0 within ~1 s after the last key event; 0x08 / 0x16 are cleared when it reaches 0. Looks like the key-release timeout of the radio link 0 7 - 0
0x08 8 bits key Key currently pressed on the remote: 1 = ▼, 2 = ▲, 4 = ESC, 8 = OK (verified 17/11/2026 with /api/keywatch). ⏻ not tested (224 seen once on 16/11, meaning unknown). Stays set ~0.7 – 1.2 s, until 0x24 reaches 0 0
0x2E 46 Sec Countdown since last contact Remote Control 0 - 240
0x30 48 x Sec While RAM 0x33 shows an error: seconds until the stove acts on it (alarm / switch-off). 55 for E1 (verified 18/11/2026) 55 55 - 0
0x31 49 x sec Seconds countdown 0 - 59
0x32 50 x Min Countdown when to start brazer cleaning 45 45 - 0
0x33 51 bitmask error Errorcode in a bitmask? 32 = E1 ? 32
0x34 52 x amount Flame power the stove actually runs at (modulates to 1 at the set point; setting is EEPROM 0x7F). Seen 1 with setting 2 in standby after reaching the set point 1 - 4
0x37 55 (x+25)*10 rpm smoke fan RPM 130 (== 1550 )
0x3E 62 x °C Fume temperature 105
0x44 68 x/2 °C Stove room temp ??
0x48 72 (x+25)*10 rpm smoke fan RPM 130 (== 1550 )
0x4B 75 x Counter 0 - 254
0x4C 76 Flips between 0 and 255
0x4D 77 x Flip flop 0 / 1 0 - 1
0x4F 79 Random ???
0x50 80 x Min Time remaining pellets when low 0
0x55 85 Looks random
0x56 86 Looks random
0x57 87 Random? Jumps every second
0x58 88 Looks random
0x59 89 Looks random
0x5A 90 Looks random
0x5B 91 Looks random
0x68 104 Looks random
0x6B 107 Sec Countdown since last contact Remote Control 0 - 240
0x6D 109 x Sec Time till error code becomse active 20 0 - 20
0x79 121 Unknown Boolean value
0x7A 122 x Sec Current time (sec) 1 0 - 59
0x7B 123 x id Day of week 1=mon / 7=sun 1 1 - 7
0x7C 124 x Hour Current time (hour) 8 0 - 23
0x7D 125 x Min Current time (min) 12 0 - 59
0x7E 126 x day Current Day 28 1 - 31
0x7F 127 x month Current Month 1 1 - 12
0x80 128 x year Current year 22 0 - 99
0x81 129 x Low byte of the stove clock as seconds since midnight / 2 (16-bit LE with 0x82; +1 every 2 s). Verified 17/11/2026: 0x82/0x81 = 4/247 -> 1271 × 2 s = 00:42:22, stove clock 00:42:22. Also matches the 16/11 16:32 dump (116/46 -> 16:31:24) 0 - 255
0x82 130 x High byte of the seconds-since-midnight / 2 counter (see 0x81); 0 – 168, back to 0 at midnight 0 - 168
0x89 137 x Min Countdown till low pellet alarm starts (hypothesis). 16/11/2026, while working: dropped 20 -> 19 and back after ~35 s, first at 19:02, then about every 9.5 – 13.5 min until shutdown; never while off. Possibly the hopper level sensor briefly seeing no pellets (unconfirmed; 0xA4 did not change in the log) 20 20 - 0
0x8F 143 x/2 °C Remote control temp
0x96 150 Unknown 84 - 89
0xAB 171 Looks random
0xAF 175 Unknown. 47 – 48 off (stove cold, 17/11/2026), 68 working. Possibly a board / electronics temperature in x/2 (23.5 °C vs 34 °C) - unconfirmed
0xB6 182 x bits Active "INSTELL WIRELESS" (external wireless temperature sensor, manual §23.9). Bit 0 = 1: off, bit 0 = 0: on. Bit 1 unknown (seen 1, 3 = off, 2 = on). Read-only: restored by the stove right after a write 1
0xC2 194 Looks random (0 - 2 - 6 - 7 )
0xC4 196 Looks random
0xC6 198 x Counter 0-255 fast 0 - 255
0xD0 208 x/2 °C Stove room temp ??
0xD2 210 Unknown 58 / 57
0xA7 167 x Second room fan drive value: 0 off, 86 / 82 / 78 at speed 1 / 2 / 3 (meaning unknown, possibly a triac delay) 82
0XD3 211 x Bool Room fan is running (0 = stopped, 2 = running)
0xDF 223 x/10 rpm Feed rate ???

Low pellets changes ( To check when pellets are low again)

0x97 (151) = 0 => 3 ?? | 0 == No Pellets / 3 == All normal => Verified, looks correct 0xC7 (199) = 2 => 0 ?? | 2 == No Pellets / 0 == All normal? 0xBB (187) = 0 => 30 | 0 == No Pellets / 30 == All Normal? 0xA4 (164) = 5 => 0 | 5 == No Pellets / 0 == All normal ======= !!!! 0x9E (158) = 76 => 77 | 76 == No pellets / 77 == All normal

EEPROM (0x20)

ADDR (HEX) ADDR (DEC) Formula Unit Description Example or default value Range
0x02 x Min Interval between braizer cleanings 45
0x04 4 x/10 Auger value at ignition (by analogy; earlier listed as kg/h) 27 == 2.7
0x05 5 x/10 Auger value at power 1 (RAM 0x0D shows 3.0 at power 1, verified 16/11/2026; earlier listed as kg/h) 30 == 3.0
0x06 6 x/10 Auger value at power 2 (RAM 0x0D shows 4.6 at power 2, verified) 46 == 4.6
0x07 7 x/10 Auger value at power 3 (RAM 0x0D shows 6.2 at power 3, verified 17/11/2026) 62 == 6.2
0x08 8 x/10 Auger value at power 4 (by analogy) 78 == 7.8
0x09 9 x/10 Auger value at power 5 (unused, the stove has 4 levels) 78 == 7.8
0x3C 60 x bool Timer PR1 enabled 0 0 - 1
0x3D 61 val×10min HH:MM Timer PR1 on time (144 = off) 144 0 - 144
0x3E 62 val×10min HH:MM Timer PR1 off time (144 = off) 144 0 - 144
0x3F 63 x °C Timer PR1 setpoint 21 7 - 30
0x40 64 x level Timer PR1 flame power 2 1 - 5
0x41 65 x speed Timer PR1 room fan speed 0 0 - 3
0x43 67 bitmask days Timer PR1 days of week see below
0x48 72 x bool Ext Thermostat Modulate = 0 / Stop = 1 0 0 - 1
0x49 73 x bool Ext Thermostat N.O. = 0 / N.C. = 1 0 0 - 1
0x4B 75 x bool Beep is enabled 1 0 - 1
0x4F 79 x id Language remote, see lookup table 1 1 - 8
0x50 80 x bool Timer PR2 enabled 0 0 - 1
0x51 81 val×10min HH:MM Timer PR2 on time (144 = off) 144 0 - 144
0x52 82 val×10min HH:MM Timer PR2 off time (144 = off) 144 0 - 144
0x53 83 x °C Timer PR2 setpoint 7 - 30
0x54 84 x level Timer PR2 flame power 1 - 5
0x55 85 x speed Timer PR2 room fan speed 0 - 3
0x57 87 bitmask days Timer PR2 days of week see below
0x58 88 x bool Timer PR3 enabled 0 0 - 1
0x59 89 val×10min HH:MM Timer PR3 on time (144 = off) 144 0 - 144
0x5A 90 val×10min HH:MM Timer PR3 off time (144 = off) 144 0 - 144
0x5B 91 x °C Timer PR3 setpoint 7 - 30
0x5C 92 x level Timer PR3 flame power 1 - 5
0x5D 93 x speed Timer PR3 room fan speed 0 - 3
0x5F 95 bitmask days Timer PR3 days of week see below
0x60 96 x bool Timer PR4 enabled 0 0 - 1
0x61 97 val×10min HH:MM Timer PR4 on time (144 = off) 144 0 - 144
0x62 98 val×10min HH:MM Timer PR4 off time (144 = off) 144 0 - 144
0x63 99 x °C Timer PR4 setpoint 7 - 30
0x64 100 x level Timer PR4 flame power 1 - 5
0x65 101 x speed Timer PR4 room fan speed 0 - 3
0x67 103 bitmask days Timer PR4 days of week see below
0x68 104 x bool Timer PR5 enabled 0 0 - 1
0x69 105 val×10min HH:MM Timer PR5 on time (144 = off) 144 0 - 144
0x6A 106 val×10min HH:MM Timer PR5 off time (144 = off) 144 0 - 144
0x6B 107 x °C Timer PR5 setpoint 7 - 30
0x6C 108 x level Timer PR5 flame power 1 - 5
0x6D 109 x speed Timer PR5 room fan speed 0 - 3
0x6F 111 bitmask days Timer PR5 days of week see below
0x70 112 x bool Timer PR6 enabled 0 0 - 1
0x71 113 val×10min HH:MM Timer PR6 on time (144 = off) 144 0 - 144
0x72 114 val×10min HH:MM Timer PR6 off time (144 = off) 144 0 - 144
0x73 115 x °C Timer PR6 setpoint 7 - 30
0x74 116 x level Timer PR6 flame power 1 - 5
0x75 117 x speed Timer PR6 room fan speed 0 - 3
0x77 119 bitmask days Timer PR6 days of week see below
0x7D 125 x °C Setpoint Room Temperature 23
0x7F 127 x amount Flame power level 1 - 4
0x81 129 x speed Room fan speed 0 0 - 3
0x90 144 x °C Energy saving Stop offset 0 - 3
0x91 145 x * -1 °C Energy saving START negative offset 0 - 3
0xC0 192 x id Combustion Quality, see lookup 76
0xC6 198 x bool Low pellets monitoring 1 0 - 1
0xC4 196 x bool Pellet contact N.O. = 0 / N.C. = 1 (verified 17/11/2026) 0 0 - 1
0xE0 224 x error Memory Error - Position 1 - See table
0xE1 225 x error Memory Error - Position 2 - See table
0xE2 226 x error Memory Error - Position 3 - See table
0xE3 227 x error Memory Error - Position 4 - See table
0xE4 228 x error Memory Error - Position 5 - See table
0x8A 138 ASCII Firmware variant char 0 A
0x8B 139 ASCII Firmware variant char 1 R
0x8C 140 x Firmware product number 1
0x8D 141 x Firmware major version 31
0x8E 142 x Firmware minor version 1
0x8F 143 x Firmware patch version 0
0xBC 188 x id Pellet quality, see combustion quality lookup
0xE7 231 x hours Hours since last service
0xEA 234 x hours Total runtime low byte (16-bit LE)
0xEB 235 x hours Total runtime high byte (16-bit LE)
0xEC 236 x hours Working hours ???
0xEE 238 x amount Amount of starts low byte (16-bit LE) 1
0xEF 239 x amount Amount of starts high byte (16-bit LE)
0xF8 – 0xFD 248 – 253 BCD Clock, see below (0xF9 hour, 0xFA minute)

Clock (EEPROM 0xF8 - 0xFD)

Written as BCD (e.g. 16 -> 0x16): 0xF8 day of week (1 = Monday ... 7 = Sunday), 0xF9 hour, 0xFA minute, 0xFB day, 0xFC month, 0xFD year (2 digits). Older firmware wrote the week number (%W) into 0xF8, which put the chrono timers on the wrong days.

Timer encoding

Each timer (PR1–PR6) occupies an 8-byte block in EEPROM. PR1 starts at 0x3C; PR2–PR6 follow at 0x50, 0x58, 0x60, 0x68, 0x70.

Time value encoding (on/off time fields):

Value Time
0 00:00
1 00:10
6 01:00
142 23:40
143 23:50
144 off

Formula: minutes = value × 10, times are in 10-minute steps only.

Day-of-week bitmask (offset +7):

Bit Value Day
0 1 Monday
1 2 Tuesday
2 4 Wednesday
3 8 Thursday
4 16 Friday
5 32 Saturday
6 64 Sunday

Example: Monday + Wednesday + Friday = 1 + 4 + 16 = 21

menu Item on remote (RAM 0x1A)

Not fully completed yet

int Selected Item
0 Main screen
1 Multifuoco
2 Chrono
3 Language
5 Clock
7 Multicomfort
8 Multi Comfort Plus
9 Energy Saving
11 Beep
12 Display
13 Installer
39 -- FILL AUGER
40 -- Pellet reserve
41 -- Pellet contact
42 -- External Thermo
43 -- Memory
51 ---- Total Hours
52 ---- Interval hours
53 ---- Amount of starts
54 ---- Error Memory
44 -- Pellet quality
46 -- Instell wireless
47 -- Link wireless
49 -- Wifi
64 ---- WPS
65 ---- Wifi Reset
14 State Stove
50 -- Parameters
15 exit

Selected in menu (RAM 0x18)

ID Selected Item
0 nothing
217 Instell wireless
71 Multi Comfort
76 Beep
79 Display settings
80 Language
123 State Stove
128 Flame power
130 MultiFuoco
145 Energy Saving - Stop
146 Energy Saving - Start
193 Combustion quality
197 Pellet contact
198 Pellet quality
199 Pellet reserve
200 Multi Comfort Plus
248 Day of week
249 Hour
250 min
251 Day
252 Month
253 year

Error codes

Val Binary Error Code Description
0 00000000 - No Error
1 00000001 E8 Fume sensor error
2 00000010 E4 Fume temperature too high
4 00000100 E9 Ignition temperature not reached within limit
8 00001000 E7 Fume temperature too low
16 00010000 E3 Temperature inside stove too high
32 00100000 E1 Pellet loading door is open for too long or air pressure inside stove is wrong
64 01000000 E2 Pressure sensor error during ignition
128 10000000 E6 Auger error - Too many pellets dispatched
129 10000001 E12 Fume fan error
130 10000010 E11 Unknown error - Not described in manual
132 10000100 E19 External contact N.PEL / Pellet is active
136 10001000 E13 Unknown error - Not described in manual
255 11111111 Power Error Display shows power error

Couldn't reverse the following error codes :

  • E10
  • E14

Language

Val Language
1 ENG
2 FRA
3 DEU
4 NLD
5 POR
6 SPA
7 HRV
8 DAN

Combustion Quality

Val Setting
76 +G
2 -3
3 -2
4 -1
5 0
6 +1
7 +2
8 +3

Pellet Quality

Val Setting
0 -5
1 -4
2 -3
3 -2
4 -1
5 0
6 1
7 2
8 3
9 4
10 5

INSTELL WIRELESS (wireless temperature sensor)

Installer menu INSTELL WIRELESS (menu 46 in RAM 0x1A, parameter 217 in RAM 0x18) enables or disables the optional external wireless temperature sensor (manual §23.9). It was first assumed to select remote vs. stove sensor; according to the manual that choice is made in the MULTICOMFORT menu (AFSTAND. / KACHEL / WIRELESS, §18), whose register is not known yet. Without contact with the remote / wireless sensor for more than 4 minutes the stove uses its own sensor, which matches RAM 0x01 following the stove sensor when the remote batteries were removed.

Observed sequence when changing it on the remote control:

  1. Opening the menu: 0x1A = 46, the stove sets 0x15 = 217.
  2. Starting to edit: 0x18 = 217, 0x19 = current value.
  3. Changing the value (not confirmed): 0x19 changes, 0x16 = 1 briefly, 0xB6 unchanged.
  4. Confirming: 0x18 = 0, 0xB6 changes (bit 0).

Nothing changes in EEPROM (bank 0x20, 0x00 - 0xFF) when the setting is confirmed. Banks 0x40 and 0x60 do not answer.

Write attempts over the serial bus, none of which changed the active setting:

Attempt Result
RAM 0x19 = 1 overwritten by the stove
RAM 0xB6 = 2 / = 1 (with and without the remote present) restored by the stove immediately
0x18 = 217, 0x19 = new value, 0x18 = 0 writes stick, no confirm
same, with menu opened first (0x1A = 46) no confirm
same, plus 0x16 = 1 no confirm

The confirm trigger is most likely a key event from the remote control. RAM 0x08 turned out to hold the pressed key (see the key watch section below); whether writing it makes the stove act on a key is not tested.

Hypotheses from the 16/11/2026 analysis (stove working, flame 2, fan 1)

Not verified with a controlled change unless stated. Sources: a full RAM + EEPROM dump, 10 samples of the unknown RAM addresses over 3 minutes, and public Micronova maps (eni23/micronova-controller, RidiculousLab, k3a.me). Maps differ per board; only 0x01, 0x0D, 0x21, 0x34, 0x37 and 0x3E match ours.

Address Observation Hypothesis
RAM 0x0A 0 / 21 / 23 / 25 at fan off / 1 / 2 / 3 with flame 2, 9 / 14 / 19 with flame 1 (verified) Room fan power; eni23 lists it as "hot air outgoing fan power"
RAM 0x02, 0x27 (copy) Always exactly fumes temperature (0x3E) − 30, in 36 samples over three sessions (working and standby) Confirmed: derived from the fume temperature (offset 30); not a separate sensor
RAM 0x07 Counts down 4 → 1, one step per minute, then restarts while working; stays 1 in standby Minute countdown of a 4-minute cycle that only runs while burning; what the cycle does is unknown
RAM 0x81 +1 about every 2 s, wraps at 255 Free-running counter
RAM 0x0B, 0x4E (copy) 104–105 while working (doc: 0 when off) Unknown, follows on/off
RAM 0x36 154 while 0x37 was 155 (1800 rpm) and later 154 (1790 rpm); in standby 234 while 0x37 was 234–235 (2590–2600 rpm) Fume fan target speed, 0x37 the measured speed (same encoding)
RAM 0x61–0x64 80 / 95 / 110 / 120 = EEPROM 0x86–0x89 RAM copy of a per-power-level parameter (4 levels)
RAM 0x6D, 0x79, 0x89 20 = set point Refuted 17/11/2026 (stove off): set point changed 20 → 21 on the remote (EEPROM 0x7D = 21), all three stayed 20, and no other stable RAM register changed (full dump). The set point is only kept in EEPROM 0x7D, at least while the stove is off; the 20 is a coincidence. Not checked while working
RAM 0xE0–0xFF All 0x20 (spaces) except E8 / EA / FD Looks like a text buffer, empty on the main screen (test: dump while a menu or message is shown)
EEPROM 0x92–0xB9 Rows of 5 values, the 5th equal to the 4th (stove has 4 power levels), 4 rows repeated twice Installer table per power level (auger time / fume fan); which row is which is unknown
RAM 0x96, 0x9E, 0xAF Change by ±1–2 between reads; 0xAF rose 68 → 75 in an hour Raw sensor (ADC) values; meaning unknown
RAM 0x33 (start-up) 17/11/2026 12:31: shows 32 (E1) for ~45 s during the start-up check (state 1), then clears; not stored in the error memory Pre-warning of the start-up check, not an error. The firmware now waits 3 min before counting an error in the transitional states (1, 2, 3, 5, 6), 30 s otherwise, and at once in an alarm state
RAM 0x33 Shows 129 (E12, fume fan) for 1–5 s when the stove enters and leaves brazier cleaning, while the stove keeps running and nothing is stored in the error memory Short pre-warning, not an error. The firmware only counts an error after 30 s or when the stove is in an alarm state (8, 9, 10)
RAM 0x32 37 at 16:06, 0 at 16:43 (brazier cleaning started), 35 at 16:54 Confirmed: minutes until the next brazier cleaning (cycle ≈ 45 min at flame 2)

PELLET RESERVE (installer menu 40, parameter 199)

Verified 16/11/2026 on the remote (menu shows ON): RAM 0x1A = 40, 0x18 = 199, 0x19 = 1. The setting is stored in EEPROM 0xC6 (1 = ON).

Parameter ids in RAM 0x18 map to EEPROM address = id − 1 for all settings checked so far (CHRONO verified 16/11/2026: PR1 on/off = parameter 61 = EEPROM 0x3C, so program n field f = parameter timerBase[n] + f + 1, i.e. PR1 61–68, PR2 81–88, PR3 89–96, PR4 97–104, PR5 105–112, PR6 113–120): 76 beep → 0x4B, 80 language → 0x4F, 128 flame → 0x7F, 130 MultiFuoco → 0x81, 145 / 146 energy saving → 0x90 / 0x91, 193 combustion quality → 0xC0, 197 pellet contact → 0xC4, 199 pellet reserve → 0xC6. Exception: 198 pellet quality is read from 0xBC (0xC5 holds 137, meaning unknown).

lowPalletAlarm is computed from RAM 0xA4 (5 = reserve sensor active) and RAM 0x89 (≤ 1 = alarm). With the hopper not empty: 0xA4 = 0, 0x89 = 20. Whether 0x89 is a remaining-time counter that starts when the sensor triggers is not verified. It is not a copy of the set point: it stayed 20 when the set point was changed to 21 (17/11/2026). | Room fan in standby (superseded: power 9 is the reduced power, see "Modulation when the set point is reached") | At 17:27, 13 min after standby started, with fumes at 108 °C: 0x0A 21 → 9, 0xA7 86 → 104, 0xD3 2 → 1, 0x04 2 → 1, 0x66 21 → 5 | The stove keeps the room fan running at a low cooling power (9) after the flame is out. 0xD3 = 1 / 0x04 = 1 probably mean "cooling run" (2 = normal run). The app shows this as "running at low power" | | RAM 0x09, 0x43 | 10 while working, 0 in standby | Follow the burning phase | | RAM 0x39 | 16 while working, 80 in standby | Unknown, changes with the phase |

Update 16/11/2026 ~17:50 (the "cooling" name was later replaced by "reduced", see below): in standby with the fan stopped (0x0A = 0, 0xA7 = 0, 0x04 = 0) RAM 0xD3 still reads 1, so 0xD3 = 1 does not mean "cooling run". The firmware derives roomFan.mode from the power 0x0A instead (0 = off, 21/23/25 = normal, other = low-power run after the flame is out) and the web app shows a cooling run as "Afkoelen" in the status and in the chart (drawn at 0.5 in the fan lane when the fan has power but no mapped speed).

Update 17/11/2026: remote display in standby with energy saving. The stove state stays 7 the whole time, but standby has two phases. 15:05 standby starts and the fume fan keeps running at ~2600 rpm (cool-down, fumes 106 → 65 °C); 15:40 the fume fan stops (0 rpm), 15:42 the room fan stops (0x0A = 0). At 16:19 the remote showed, in big letters, OFF / ENERGY / OK with the chrono icon and "E" (no signal icon). Hypothesis: the remote switches to this screen when the fume fan stops; what it shows during the cool-down (15:05 – 15:40) has not been seen yet. The web app shows "OFF / ENERGY / OK" in state 7 with energy saving once the fume fan speed is 0.

Update 17/11/2026 19:41 – 20:05 (pellets running low, stove working at flame 1): RAM 0xA4 (level sensor) went 0 → 5 at 19:41:47 and RAM 0x89 counted down 20 → 0, one step about every minute (20 steps in 19 min; read every ~37 s, so the logged steps are 37 / 74 s apart), reaching 0 at 20:00:49. The stove kept working (state 4 at 20:05). Confirmed: RAM 0x89 = minutes until the pellet reserve alarm, counting while 0xA4 = 5. The earlier short dips 20 → 19 → 20 were the sensor briefly seeing low pellets. RAM 0x50 ("min remaining") stayed 0 the whole time: not this timer. Also stable during the countdown: 0x97 = 0, 0xBB = 0, 0x9E = 77, 0x96 = 193; 0xC7 1 → 0. Phase 2: once RAM 0x89 is 0 the remote shows PELLET RESERVE xx' on the main screen (18' at 20:12) and RAM 0x91 counts down in steps of exactly 30 s (key watch: steps at 21.2 / 51.4 / 81.5 s; 35 at 20:14, 22 at 20:20:51, 19 at 20:22) until the stove switches off: about 30 min after 0x89 reached 0. RAM 0x91 = half minutes until the stove switches off (remote ≈ 0x91 / 2; the exact rounding of the remote not checked against a simultaneous reading). Expected switch-off around 20:31. Not reached: the hopper was refilled first. Refill seen in the event log: 20:27:13 error E1 (pellet loading door open) for 6 s while the hopper lid was open, 20:27:30 RAM 0xA4 5 → 0 and RAM 0x89 0 → 20 (reserve reset), 20:30:39 working → standby (energy saving). So E1 = the hopper lid (loading door) switch; the short E1 seen during the start-up check is probably the stove testing that switch (observation, not confirmed).

Update 17/11/2026 16:38 – 16:40 (stove restarting by energy saving, state 2 pellet loading): RAM 0x2F counted down 208 → 145 in 63 s (~1 per second) and RAM 0x31 56 → 53, 0x07 1 → 4. Supports 0x2F = countdown in seconds of the current phase, now also seen in the start-up phase. In this phase: 0x09 / 0x43 = 0 / 10, 0x39 = 16, 0x36 = 0x37 = 119 (1440 rpm fume fan), 0x0A = 0 (room fan off, 0x04 = 0 too cold), 0xAF = 56, 0xA1 = 214.

PELLET CONTACT (installer menu 41, parameter 197)

Verified 17/11/2026 on the remote, stove in standby (state 7). Changing CONTACT PELLET from N.O. to N.C.: RAM 0x1A = 41 (menu), 0x18 = 197 while editing and 0 after confirming, 0x19 followed the value shown (0 = N.O., 1 = N.C.). The setting is stored in EEPROM 0xC4 (0 = N.O., 1 = N.C.), in line with id − 1. A full EEPROM dump before, after and after setting it back showed no other change apart from the clock (0xF9 / 0xFA, hour and minute in BCD). The stove raised no error (no E19) with N.C.; it was set back to N.O. the same evening.

ERROR COUNTDOWN (RAM 0x30)

Verified 18/11/2026 ~08:20, stove working (state 4), key watch on RAM 0x21, 0x33, 0x30, 0x2F, 0x31, 0x07, 0x2C, 0x2D. Opening the hopper lid: RAM 0x33 0 → 32 (E1), the remote beeps; one second later RAM 0x30 counts down from 55, one step per second (55 → 19 in 36 s). Lid closed after ~36 s: 0x33 → 0 and 0x30 back to 55 at once; the stove kept working and stored no error. So the stove gives about 55 s before it acts on E1 (switch-off / alarm, assumed at 0x30 = 0, not observed). Whether other errors use the same 55 s is not verified. RAM 0x31 counts 59 → 0 every minute (seconds) and 0x07 drops by 1 each time 0x31 wraps; 0x2F, 0x2C, 0x2D did not change.

DISPLAY – backlight (menu 12, parameter 79)

Verified 16/11/2026: the screen "SET ACHTERGRONDVERLICHTING ON 10 s" is menu 12, parameter 79 (EEPROM 0x4E = 1). RAM 0x19 stays 1 while the value on the remote is changed (10 s → 9 s), so the backlight time is kept in the remote itself and is not visible over the stove bus. The screen "SET POWER ON 31 s" in the same menu also shows parameter 79 with 0x19 = 1: all DISPLAY screens look the same on the bus, so it cannot be told which one is open.

STAAT KACHEL (menu 14, parameter 123)

Verified 16/11/2026: menu 14 without a parameter is the menu screen (stove icon + "STAAT KACHEL"); after OK the parameter is 123 and RAM 0x19 is the page:

0x19 Page (texts on the remote)
0 TERM EXT=OFF, DATA BANK=08, FW-AR-01-V-31-01-00
1 ROOKG=084°, RPM/ASP=1800, SCHROEF=04.6, KACHEL=24°, AFSTAND.=20°< (< marks the sensor used for the room temperature; temperatures truncated)
2 SENSOR 1=DISAB, ID SENSOR 1=DISAB

The registers behind TERM EXT, DATA BANK and SENSOR 1 / ID SENSOR 1 are not known yet.

Modulation when the set point is reached (verified 16/11/2026 18:53)

Room 20.0 → 20.5 °C with set point 20, flame set to 2, fan set to 1. The stove turned down at once:

Before After
Actual flame power (RAM 0x34) 2 1
Auger (RAM 0x0D) 4.6 (= EEPROM 0x06) 3.0 (= EEPROM 0x05)
Fume fan target / actual (RAM 0x36 / 0x37) 154 / 154 (1800 rpm) 134 / 134 (1590 rpm)
Room fan power (RAM 0x0A) 21 9
RAM 0xA7 86 104
RAM 0xD3 / 0x04 2 / 2 1 / 1

Follow-up the same evening (stove still at flame 1): changing the fan speed gave 0x0A = 9 / 14 / 19 for speed 1 / 2 / 3 (0xA7 = 104 / 97 / 89). Together with 21 / 23 / 25 at flame 2 this shows that the room fan power depends on the selected speed and the actual flame power; there is no separate reduced mode. 0xA7 ≈ 117 − 1.5 × 0x0A, consistent with a triac delay derived from the power. The firmware now reports roomFan.actual = selected speed while the power is > 0 and roomFan.mode = off / on. The main screen of the remote shows the room temperature inverted (white on black) in this situation.

Off vs. working (17/11/2026)

Stove off for 2.5 h (state 0, room 17 °C, stove sensor 20 °C, fume 22 °C), compared with the working dump of 16/11 16:32 (flame 2, fume 93 °C). Registers that differ and stay stable while off; meaning not known yet:

RAM Working Off Note
0x0B 104 0 Already known as "0 off, ~100 on"
0x0E 2 1
0x12 103 110
0x14 0 1 Listed as boolean
0x1F 158 144
0x20 0 8
0x22 51 1 Listed as boolean, but 51 while working
0x2F 10 20
0x38 26 30
0x3A 0 2
0x4E 104 0 Same value as 0x0B while working
0xA1 214 0
0xAF 68 47 – 48 See table above
0xB7 230 234
0xC6 143 75 Listed as fast counter, but stable while off
0xC7 0 2
0xC8 147 89
0xFA 32 69 (E) Rest of 0xE0 – 0xFF stays 32

Free-running while off (sampled every ~8 s for 2 min): 0x00, 0x13 (wraps at 120), 0x4B (~5 per second), 0x4F, 0x55 – 0x5B, 0x68, 0xAB, 0xC2, 0xC4 – look like counters or noise. 0x2E / 0x6B count down and reset about every 68 s (remote contact, as documented). 0x23 creeps up 1 → 7. 0x83 is 200 with short dips to 193 – 198 and 0x96 moves between 36 and 42: possibly analog readings.

Brazier cleaning at flame 3 (17/11/2026 09:28)

Stove working at flame 3 (actual 3), fan speed 1, fumes 136 °C. 41 RAM addresses sampled every ~7 s from 09:28:05 to 09:30:47; the brazier cleaning (state 5) ran from about 09:28:41 to 09:29:10.

RAM Before During cleaning After Conclusion
0x21 4 5 4 State
0x2F 10 25 → 18 → 11 → 3 (~1 per second) 10 Hypothesis: countdown in seconds of the current phase. The cleanings in the log lasted 24 – 26 s. 20 while off
0x32 1 3 45 → 44 → 43 Minutes to the next cleaning (confirmed). Shows 3 during the cleaning itself (0 on 16/11)
0x36 / 0x37 178 / 179 238 / 238 – 239 178 Fume fan target / actual: the fan speeds up to ~2630 rpm for the cleaning
0x0D 62 (6.2) 33 (3.3) 62 Auger: 6.2 = EEPROM 0x07, so the flame 3 value is verified. 3.3 during cleaning matches no EEPROM auger value
0x09 / 0x43 10 / 10 3 / 2 → 0 / 0 10 / 10 Drop during cleaning (also 0 in standby)
0x0B / 0x4E / 0x12 105 / 105 / 104 102 / 102 / 101 105 / 105 / 105 Move together
0x07 1 4 4 → 3 → 2 (per minute) The 4-minute cycle restarted at the cleaning

Other findings at flame 3:

  • Room fan power RAM 0x0A = 27 at speed 1 (0xA7 = 74). Speed 2 / 3 at flame 3 not measured yet.
  • RAM 0xD3 = 3, RAM 0x04 = 3, RAM 0x0E = 3. With the earlier values (0xD3 / 0x04 = 1 at flame 1, 2 at flame 2; 0x0E = 2 at flame 2, 1 off) all three follow the actual flame power. 0xD3 stays at least 1 (also with the fan stopped, which is why it looked unreliable); 0x04 is 0 while the stove is too cold for the fan.
  • RAM 0x36 = 178 vs EEPROM 0x13 = 180 (and 134 / 154 vs 0x11 / 0x12 = 135 / 155): EEPROM 0x10 – 0x15 is very likely the fume fan target per power level. RAM is 1 – 2 lower, possibly because combustion quality is set to −1.
  • RAM 0xA1 = 238 (214 at flame 2, 0 off): depends on the power.
  • RAM 0xAF = 92 – 93 (68 – 75 at flame 2, 47 – 48 cold): keeps rising while burning, consistent with a temperature in x/2.
  • RAM 0xC6 / 0xC8 = 75 / 89, 0x14 = 1, 0x22 = 1, 0x3A = 3, 0xC7 = 2: the same as (or close to) the values with the stove off. These do not follow on / off as the 16/11 comparison suggested.
  • RAM 0x89 kept dipping 20 → 19 for ~37 s while working (08:20, 08:34).
  • EEPROM 0x0A – 0x0F = 55 / 25 / 17 / 155 / 35 / 150, meaning unknown.

Remote control keys (17/11/2026, /api/keywatch)

The GRF remote talks to the stove board over radio; that traffic is not on the serial bus. RAM 0x08, 0x15, 0x16, 0x18, 0x19, 0x1A and 0x24 were read back to back (19.9 reads per second, ~0.35 s per address, no read errors) for 2 minutes while the keys were pressed on the remote (stove working).

Key RAM 0x08 Effect seen
▼ 1 Main screen: opens the set point (0x18 = 126, 0x19 = set point); in an edit: 0x19 − 1
▲ 2 Main screen: opens the set point; in an edit: 0x19 + 1
ESC 4 Leaves the menu (0x1A → 0)
OK 8 Main screen: opens the menu (0x1A = 1, 0x15 / 0x18 = 130 MULTIFUOCO); in a menu enters / leaves the parameter (0x18 130 ↔ 0); in the set point screen confirms and closes it (0x18 → 0)
⏻ ? Not pressed
  • 0x08 is set at the key press and cleared together with 0x16 when 0x24 counts down to 0, ~0.7 – 1.2 s later. The values look like bits, so a combination of keys may give the sum (not tested).
  • 0x16 counts the key events of one press: 1 on the press, then +1 for every auto-repeat step while held (37 after holding ▼ ~9 s). Every step changes 0x19 by one; during a long hold the stepping accelerates and the value wraps within 7 – 30.
  • 0x24 jumps to 3 – 7 at every key event and counts down to 0; the key is released when it reaches 0.
  • Order within one sample round: 0x24, 0x08, 0x16 change first, then 0x18 / 0x19 / 0x1A, so the stove handles the key right after storing it.

Writing a key from the serial bus (17/11/2026, remote on the main screen)

Write Read back (first read ~1 s later) Effect
RAM 0x08 = 2 (▲) 0x08 = 224, 0x16 = 1, 0x24 = 0; all 0 a second later None: no set point screen (0x18 stayed 0)
RAM 0x24 = 7, then 0x08 = 2 (60 ms later) 0x08 = 16, 0x16 = 1, 0x24 = 2 → 0; all 0 two seconds later None: no set point screen, stove state unchanged

The stove accepts the writes and counts a key event (0x16 = 1), but rewrites 0x08 to another value (224 / 16, meaning unknown) and nothing happens on the remote (checked on the remote itself: no screen change, no beep). Hypothesis: the menus run in the remote itself (it also keeps the display settings, see DISPLAY above); 0x08 / 0x16 / 0x24 only report the key to the stove, so writing them cannot drive the remote. Emulating keys this way does not work; a virtual remote would need the radio link. Settings are better written directly (set point, flame, fan, ... as the API does).