Skip to content

L200 baseline HVAC workflow - #33

Open
JieXiong9119 wants to merge 4 commits into
developfrom
l200-baseline-hvac
Open

JieXiong9119 wants to merge 4 commits into
developfrom
l200-baseline-hvac

Conversation

@JieXiong9119

@JieXiong9119 JieXiong9119 commented Nov 18, 2026 •

Copy link
Copy Markdown
Contributor

Summary

Adds L200 HVAC topology construction to the baseline: when a BuildingSync file's existing HVAC system exactly matches a supported topology, BOSS builds that topology instead of relying on create_typical_building_from_model's generic HVAC. All other cases keep today's fallback behavior.

This pulls the baseline + HVAC part of scenario-workflow branch (up to #30) into develop on its own, ahead of the package-scenario work. Scenario mapping, scenario OSW writing/running, modifier binding, and retrofit fixtures stay on scenario-workflow.

Behavior

  • Topology baseline: when every non-proposed HVACSystem exactly matches one supported configuration (PTAC, PTHP, four-pipe fan coil, packaged rooftop AC/heat pump, packaged rooftop VAV or VAV with hot-water reheat, warm air furnace, VRF; optionally plus ventilation-only/DOAS with zone equipment) that serves the whole building:
    • create_typical_building_from_model gets add_hvac: false
    • apply_hvac_topology_to_zone_scope (create, all_model_zones) then apply_standard_hvac_sizing_and_efficiency are added
    • buildingsync-measures-gem measure paths are added to measure_paths
    • Simulation coverage in this PR: packaged rooftop heat pump (2 fixtures); the other configurations are covered by selector/planner/binder unit specs.
  • Fallback baseline (no match or unsupported template): add_hvac: true, existing system_type mapping, a logged warning, and no dependency on the sibling checkout. Verified byte-identical in.osw against develop for building_151 and all_measures_applied_example.
  • No changes to public APIs, CLI commands/options, runner inputs, or the baseline/in.osw layout.

Changes

  • OswArgPopulator: append_step, set_step_argument, step_argument_setter, add_hvac: keyword (default true)
  • ExternalMeasureRepoManager + config/external_measure_repos.yml: local_path sources (used in place, never touched by Git; missing path is an actionable error) and the scenario_only / include_scenario_only gate so only topology baselines need ../buildingsync-measures-gem
  • BuildingSyncReader#get_hvac_systems_xml
  • New HvacTopologySelector, BaselineHvacPlanner (incl. proposed_system_ids, moved from ScenarioHvacPlanner), and HvacTargetBinder (topology binding only; bind_modifier intentionally omitted)
  • Boss.write_baseline_osw refactored onto private build_baseline_osw; run_baseline_osw unchanged
  • Fixtures: example-smalloffice-level2.xml, example-smalloffice-level2-built-2012.xml
  • CI checks out buildingsync-measures-gem as a sibling at the pinned ref in the unit and integration jobs; paths/caches/artifacts adjusted for the BOSS/ subfolder. Shards, smoke selection, and docs-only gates unchanged.
  • Two topology baseline integration examples (DOE Ref 1980-2004, 90.1-2013), run on shard 0 only and skipped with BOSS_SMOKE=1
  • README: "Baseline HVAC" section, sibling-checkout setup, add_hvac row updated

Testing

  • bundle exec rspec spec/tests/unit — 152 examples, 0 failures
  • Fallback OSW parity with develop (building_151, all_measures_applied_example) — identical
  • bundle exec rake measures:install_external + rspec spec/tests/integration/write_and_run_osws_spec.rb -e "topology HVAC baseline" — 2 examples, 0 failures (both simulations Success)
  • git diff --check — clean
  • Full integration suite / shards — via CI
  • RuboCop

Local setup

git clone https://github.com/BuildingSync/buildingsync-measures-gem.git ../buildingsync-measures-gem
git -C ../buildingsync-measures-gem checkout 789bd50

Only needed for topology baselines and the related specs.

@JieXiong9119 JieXiong9119 self-assigned this Nov 18, 2026
@JieXiong9119

Copy link
Copy Markdown
Contributor Author

Notes:

  • This PR can't merge into develop until upstream buildingsync-measures-gem PR #6 merges and the BSYNC_MEASURES_REF pin in CI points to the merged commit.
  • After this merges, update scenario-workflow so ScenarioHvacPlanner.proposed_system_ids calls the copy that now lives in BaselineHvacPlanner.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment